S100(300)-2B+KZ10(15)
Category:
- Product Description
S100(300)-2B+KZ10(15)
-
- Commodity name: S100(300)-2B+KZ10(15)
Flow range: 0.0025-134mL/min, suitable for micro-flow high-precision liquid× delivery
Product Introduction
◆ Flow range: 0.0025-134mL/min, suitable for micro-flow high-pr↑ecision liquid delivery
◆ Single and dual-channel pump heads are optional, with 4-roller and ₩8-roller options. 4-roller pump heads have a slightly larger flow rate, while 8-roller pump heads have lower pulsation.
◆ Maximum speed of 100rpm and 300rpm are optional.
◆ Pump heads can be used in series.
◆ Stepper motor drive
◆ 15-digit BCD DIP switch speed regulation, or external con∞trol signal speed regulation
◆ Switch quantity control start and stop, switch quantity control forward and reverse
◆ Flow accuracy can reach ±1%
◆ Panel or base mounting
◆ DC 24V power supply, optional power adapter, to achieve 220V AC power sγupply


Single Channel Dual Channel Phase Compensation Principle
◆ Two pump heads are connected in series, and the rollers of the front and rear↕ pump heads are staggered. The rollers of the front pump head are located between the two rollers of the rear pump head.
◆ The inlet and outlet pipelines of the front and rear pump heads are connected by three-way connecto£rs, and the liquid in the pipelines of the front and rear pump↔ heads compensate each other.
◆ Liquid pulsation is greatly reduced, and flow accuracy is above ±0.5%.

Pump Head Series Connection

◆ Two pump heads are connected in series, and the rollers of the frontδ and rear pump heads are staggered. The rollers of the front pump he★ad are located between the two rollers of the rear pump head.
◆ The inlet and outlet pipelines of the front and rea₽r pump heads are connected by three-way connectors , and the liquid in the pipelines of the front and rear pump heads c ompensate each other.
◆ Liquid pulsation is greatly reduced, and flow accuracy≠ is above ±0.5%.
Tubes Installation

◆ Press inward on both sides of the retaining clip to∑ remove it → Insert the tube assembly → Reinstall the retaining clip
Control Circuit

◆ 15-speed adjustment with BCD coded switch
◆ The BCD coded switch is set to "0" for external signal control.
◆ Terminals 1 and 2 are the input terminals for RS485 commuπnication control, 1 is positive, and 2 is negative.
◆ Terminals 3 and 4 are the external signal input terminals, 3 is positive, and 4 is nφegative. External signals include: 0-10KHz, 0-5V, 0-10V, 4-20mA, cho₩ose one.
◆ Terminals 5 and 7 control start and stop. Floating or open, theδ pump runs; closed, the pump stops.
◆ Terminals 6 and 7 control direction. Floating or open, th&e pump runs clockwise; closed, the pump runs countercl♥ockwise.
◆ Terminals 8 and 9 are the power input terminals, 9 is pos•itive, and 8 is negative. DC24V is recommended.
Technical Parameters
Product Model S100-2B+KZ10(15) S300-2B+KZ10(15) Applicable Pump Head KZ10-14 KZ10-18 KZ10-24 KZ10-28 KZ15-14 KZ15-18 KZ15-24 KZ15-28 Start/Stop Control Can control start and stop Direction Control Reversible Internal Speed Control BCD DIP switch adjustment External Speed Control 0-10kHz pulse control or 0-5V, 0-10V, 4-20mA analog signal control, c¶hoose one. 0-10KHz is standard. S100-2B Internal Speed Range 1-100rpm, 15-speed adjustment, standard configuration is 5,10,15,20,25,30,35,40,45,50,60,70,80,90,100rpm, customizable S100-2B External Speed Range 0-100rpm, speed resolution 0.1rpm, full range linear correspondence S300-2B Internal Speed Range 1-300rpm, 15-speed adjustment, standard configuration is 20 40 60 80 120...280 300rpm, cust♥omizable S300-2B External Speed Range 0-300rpm, speed resolution 0.1rpm, full range linear correspondence Communication Control RS485 communication control, using Modbus communication protocol, communication control and other external control cannot coexist, choose one. Speed Error ≤±0.5% Start/Stop Control Start/Stop Control: Normally open switch quantity control contacts, the peristalticβ pump runs; contacts are closed (port 5 and port 7 are shorted), the peristaltic p ump stops. Direction Control Direction Control: Normally open switch quantity control contacts, the peristaltic pump runs clockφwise; normally closed contacts (port 6 and port 7 are shorted), the peri✘staltic pump runs counterclockwise. Applicable Power Supply 11.4-25.2V DC; or 100-240V AC (optional power adapter) 50/60Hz Operating Environment 0-40℃, relative humidity: <80% Weight 540g Selection Guide
Peristaltic Pump Model
Speed (rpm)
Number of Rollers
Number of Channels
Applicable Tubing
Flow range (ml/min)
S100-2B+KZ10-14
100
4
1
Wall thickness 0.8-1mm, outer diameter ≤6.4mm
0.0035-45
S100-2B+KZ10-18
8
1
0.0025-18
S100-2B+KZ10-24
4
2
0.0035-45
S100-2B+KZ10-28
8
2
0.0025-18
S100-2B+KZ15-14
4
1
13# 14# 19# 16#
0.0035-42
S100-2B+KZ15-18
8
1
0.0028-18.9
S100-2B+KZ15-24
4
2
0.0035-42
S100-2B+KZ15-28
8
2
0.0028-18.9
S300-2B+KZ10-14
300
4
1
Wall thickness 0.8-1mm, outer diameter ≤6.4mm
0.0035-134
S300-2B+KZ10-18
8
1
0.0025-52
S300-2B+KZ10-24
4
2
0.0035-134
S300-2B+KZ10-28
8
2
0.0025-52
S300-2B+KZ15-14
4
1
13# 14# 19# 16#
0.0035-128
S300-2B+KZ15-18
8
1
0.0028-57
S300-2B+KZ15-24
4
2
0.0035-128
S300-2B+KZ15-28
8
2
0.0028-57
Dimensions

Related products
Get a free product quote
Fill in your phone and E-mail information, and we will contact you within one working day to s→olve your problems as soon as possible.