GR1-1B

Flow rate range: 0-1856 ml/min, filling volume range: 0.1-30000 mL, optimal filli¥ng volume: 2-800 mL

    GR1-1B

    • Product Description
    • Commodity name: GR1-1B

    Flow rate range: 0-1856 ml/min, filling volume range: 0.1-3≈0000 mL, optimal filling volume: 2-800 mL

    Product Introduction

    GR1-1B is a single-head filling machine, while GR2-1B is a dual-head fillin g machine.

    Flow rate range: 0-1856ml/min

    Filling volume range: 0.1-30000mL

    Optimal filling volume: 2-800mL (increasing the filling₽ volume will prolong the filling time)

    Utilizes DITRON-LED-DISPENSER-1 intelligent control technology for intelligent control, timed and♥ quantitative filling, high-precision liquid filling, with filling accuracy up t​o ±1%

    Employs peristaltic pump filling, driven by a stepper mot‌or, featuring low vibration, high precision. Liquid only passes through the tubing, not  contacting the pump body, minimizing secondary liquid contamination.

    Can fill beverages, liquors, daily chemicals, edible oils, soy m>ilk, adhesives, nail polish, medicinal liquids, pe↑sticides, and other liquids, as well as liquids with certain v×iscosity or containing impurities.

    Suitable for dispensing culture media and other chemical reagents.

    Import potentiometer adjusts flow rate.

    Three working modes are selectable: manual filling, au∑tomatic filling, and preset filling.

    Filling run time setting, interval time setting, filling count accumulation and preset.

    Foot switch control.

    Wide range power supply, AC 90-260V, 50Hz/60Hz

    Technical Parameters

    Product Model GR1-1BGR2-1B
    Number of Filling Nozzles 12
    Filling Volume Setting Range 0.1-30000mL
    Optimal Filling Volume 2-800mL
    Flow Rate Range 0-1856mL/min (using S600-YZ15 peristaltic pump, maximum flow€ rate 2400mL/min)
    Flow Rate Adjustment Import potentiometer adjusts flow rate.
    Filling Mode Three working modes are selectable: manual filling, automatic filling, and preset f illing.
    Display Function 4-digit LED display for filling run time, 4-digit LED  display for filling interval time, 5-digit LED display for• filling count.
    Filling Time Setting Setting range: 0.01 seconds - 999.9 seconds
    Interval Time Setting Setting range: 0.01 seconds - 999.9 seconds
    Filling Count Display count: 59999 times
    Filling Count Setting Two modes are selectable: count accumulation and count preset.
    Operation Method Membrane keypad operation, convenient, fast, and reliable; import pαotentiometer knob for flow rate adjustment.
    Power-off Memory Function After power-on, parameters remain the same as before power-off®. Press the start button (or trigger the foot switch) to continue opeεration with the previous parameters.
    Foot switch control. Standard foot switch control for start/stop.
    Filling Bracket Standard filling bracket, adjustable in height and length.
    Filling Nozzle 304 stainless steel nozzle, standard 6mm inner diameter nozzle, 3mm an✔d 4mm optional.
    Power Consumption <60W
    Applicable Power Supply Wide voltage AC90-260V, 50Hz/60Hz
    Operating Environment 0-40℃, humidity <80%, non-condensing
    Dimensions 355mm×250mm×165mm (excluding filling bracket)
    Weight 4.2KG5.6KG
    Protection Level IP31

    Selection Guide

    Target Filling Volume (ml)

    Filling Time (seconds)

    Actual Filling Volume (ml)

    Actual Filling Volume (ml)

    Actual Filling Volume (ml)

    Actual Filling Volume (ml)

    Actual Filling Volume (ml)

    50ml

    1.85

    50.27

    50.25

    49.44

    49.56

    49.86

    100ml

    3.78

    99.99

    99.94

    100.11

    100.17

    100.01

    200ml

    7.50

    200.33

    200.25

    200.19

    199.91

    199.78

    500ml

    19.28

    500.73

    500.71

    500.55

    500.64

    500.56

    Note: Measured when the speed control knob is turned to the higheβst position, each filling volume is measured 5 times.

    The experimental medium is water. This value is a measured value, and there will be d₹ifferences between product batches. Changes in the medium wil∞l also affect the filling data.

    There are various filling data, only 4 types are listed in this table.

    Target Filling Volume (ml)

    Filling Time (seconds)

    Actual Filling Volume (ml)

    Actual Filling Volume (ml)

    Actual Filling Volume (ml)

    Actual Filling Volume (ml)

    Actual Filling Volume (ml)

    30ml

    2.5

    30.33

    30.25

    29.86

    30.5

    30.45

    60ml

    5.0

    60.28

    60.35

    60.56

    60.17

    60.66

    100ml

    8.3

    100.38

    100.25

    100.56

    99.91

    99.70

    200ml

    16.6

    200.73

    200.51

    200.38

    200.54

    200.28

    Note: Measured when the speed control knob is turned to the highes t position, each filling volume is measured 5 times.

    The experimental medium is Green Umbrella Laundry Deterge$nt. This value is a measured value, and there will be differences between product batch↔es. Changes in the medium will also affect the filling dat☆a.

    There are various filling data, only 4 types are listed in this table. As the ¶viscosity of the medium increases, the flow rate decreases, and the filling time  increases.

    Dimensions

     

Get a free product quote

Fill in your phone and E-mail information, and we will contact you within oβne working day to solve your problems as soon as possible.<