S100(300)-11B+KZ10(15)
Category:
- Product Description
S100(300)-11B+KZ10(15)
-
- Commodity name: S100(300)-11B+KZ10(15)
Flow range: 0.0025-134mL/min, suitable for micro-flo≠w high-precision liquid delivery
Product Introduction
◆ Flow range: 0.0025-134mL/min, suitable for micro-flow high-precision liquid delivery
◆ Pump head single-channel and dual-channel optional, with 4-roller, 8-roller optionΩal, 4-roller pump head flow slightly larger, 8-roller pump head pulsati↓on lower
◆ Maximum speed of 100rpm and 300rpm optional
◆ Pump heads can be used in series
◆ Stepper motor drive
◆ 15-speed BCD DIP switch speed control, or external c≠ontrol signal speed control
◆ Switch quantity control start and stop, switch quantity cont₹rol forward and reverse
◆ Flow accuracy up to ±1%
◆ Panel or base mounting
◆ DC 24V power supply, optional power adapter, realizing 22±0V AC power supply


Single Channel Dual Channel Tube Installation

◆ Press inward on both sides of the pressure block to remove the pressure block → ≈Install the tubing assembly → Install the pressure block
Pump Head Series Connection

◆ Two pump heads connected in series, the rollers of the front and rear pump πheads are installed staggered, the rollers of the front pu≤mp head are located between the two rollers of the rear pump head
◆ The inlet and outlet pipelines of the front and rear pump heads are connected by a three-way connec★tion, and the liquid in the pipelines of the front and rear pump heads compensate each oth≥er
◆ Liquid pulsation is greatly reduced, flow accuracy is above ±0.5%
Phase Compensation Principle
◆ Two pump heads connected in series, the rollers of the front and rear pump heads€ are installed staggered, the rollers of the front pump head are locate♦d between the two rollers of the rear pump head
◆ The inlet and outlet pipelines of the front and rear pump heads are connected by a three≈-way connection, and the liquid in the pipelines of the front and rear pump headαs compensate each other
◆ Liquid pulsation is greatly reduced, flow accuracy is above ±0.5%

Control Circuit

◆ BCD coded switch 15-speed control
◆ The BCD coded switch is set to "0" for external signal control
◆ Terminals 1 and 2 are RS485 communication control i₽nput terminals, 1 is positive, 2 is negative
◆ Terminals 3 and 4 are external signal input terminals, 3 is positive, 4 is negative. External sign→als include: 0-10KHz, 0-5V, 0-10V, 4-20mA, one of which can™ be selected
◆ Terminals 5 and 7 control start and stop; floating or o®pen, pump runs; closed, pump stops
◆ Terminals 6 and 7 are for direction control; floating or open✔, pump runs clockwise; closed, pump runs counterclockwise
◆ 8 and 9 are power input terminals, 9 is positive, 8 is negative, recommended to use αDC24V
Technical Parameters
Product Model S100(300)-11B+KZ10(15) Applicable Pump Head KZ10-14 KZ10-18 KZ10-24 KZ10-28 KZ15-14 KZ15-18 KZ15-24 KZ15-28 Start/Stop Control Can control start and stop Direction Control Reversible in both directions Internal Speed Control BCD DIP switch adjustment External Speed Control 0-10kHz pulse control or 0-5V, 0-10V, 4-20mA analog signal contro↕l, one of which can be selected. Standard configuration is 0-10KHz S100-11B Internal Speed Range 1-100rpm, 15-speed adjustment, standard configuration is 5,10,15,20,25,30,←35,40,45,50,60,70,80,90,100rpm, customizable S100-11B External Speed Range 0-100rpm, speed resolution 0.1rpm, full-range linear correspondence S300-11B Internal Speed Range 1-300rpm, 15-speed adjustment, standard configuration is 20 40 60 80 120...280 300rpm, customizable S300-11B External Speed Range 0-300rpm, speed resolution 0.1rpm, full-range linear correspondence Communication Control RS485 communication control, using Modbus communication↔ protocol, communication control and other external control cannot coe±xist, one of which can be selected Speed Error ≤±0.5% Start/Stop Control Start/Stop Control Switch quantity control contact normally open, pe¶ristaltic pump runs; contact closed (port 5 and port 7© shorted), peristaltic pump stops Direction Control Direction Control Switch quantity control contact normally open, peristalti¶c pump runs clockwise; contact normally closed (port 6 and port 7 shorted), peri$staltic pump runs counterclockwise Applicable Power Supply 11.4-25.2V DC; or 100-240V AC (optional power adapter) 50/60Hz Operating Environment 0-40℃, relative humidity: <80% Weight 540g Selection Guide
Peristaltic Pump Model Speed (rpm) Number of Rollers Number of Channels Applicable Tubing Flow rate range (ml/min) S100-11B+KZ10-14 100 4 1 Wall thickness 0.8-1mm, outer diameter ≤6.4mm 0.0035-45 S100-11B+KZ10-18 8 1 0.0025-18 S100-11B+KZ10-24 4 2 0.0035-45 S100-11B+KZ10-28 8 2 0.0025-18 S100-11B+KZ15-14 4 1 13# 14# 19# 16# 0.0035-42 S100-11B+KZ15-18 8 1 0.0028-18.9 S100-11B+KZ15-24 4 2 0.0035-42 S100-11B+KZ15-28 8 2 0.0028-18.9 S300-11B+KZ10-14 300 4 1 Wall thickness 0.8-1mm, outer diameter ≤6.4mm 0.0035-134 S300-11B+KZ10-18 8 1 0.0025-52 S300-11B+KZ10-24 4 2 0.0035-134 S300-11B+KZ10-28 8 2 0.0025-52 S300-11B+KZ15-14 4 1 13# 14# 19# 16# 0.0035-128 S300-11B+KZ15-18 8 1 0.0028-57 S300-11B+KZ15-24 4 2 0.0035-128 S300-11B+KZ15-28 8 2 0.0028-57 Dimensions

M4 threaded hole user installation hole
Related products
Get a free product quote
Fill in your phone and E-mail information, and we will contact you within on✔e working day to solve your problems as soon as possible.