TJ-3A+W0109-1B split syringe pump

Flow range: 0.138ul-52.95ml/min, the controller and actuator are separated, suitable for syri™nges, single-channel perfusion/aspiration type micro-injection pump

    TJ-3A+W0109-1B split syringe pump

    • Product Description
    • Commodity name: TJ-3A+W0109-1B split syringe pump

    Flow range: 0.138ul-52.95ml/min, the controller and actuator are separated, suitable for syringes,​ single-channel perfusion/aspiration type micro-injection pump

    Product Introduction

    The TJ-3A+W0109 is a single-channel infusion/aspiration microliter syring∏e pump, suitable for high-precision micro-volume liquid' infusion.

    Flow Rate Range: 0.138ul-52.95ml/min

    Compact size, the controller and actuator are separate.

    User-friendly interface: large screen LCD display, digital rotary knob and membrane keypad, easΩy and quick operation.

    5 Working Modes: Infusion mode, Aspiration mode, Aspiration-Infusion mode, Infusion-Aspirati↔on mode, Continuous mode.

    Power-down Memory Function: Saves the set parameters, no need to ✘reset after power-on.

    Using RS-485 communication bus, it can be connected to a host computer for con←trol through background software.

    External Control Interface: With input/output control functions.

    Liquid Volume Calibration Function: A more accurate flow rate can be o♦btained through the calibration program.

    Typical Applications

    Biological Laboratories

    Micro-volume liquid infusion.

    Technical Parameters

    Product ModelTJ-3A+W0109-1B
    Working ModeInfusion, Aspiration, Aspiration then Infusion, Infusion then Aspiration, Cont≈inuous
    Flow Rate Range0.138ul-52.95ml/min
    Number of Syringes that can be Installed1
    Range of Syringes that can be Installed5uL-60ml
    Stroke Distance90mm
    Stroke Resolution0.156μm
    Linear Velocity Range7.94 um/min-79.4mm/min (Flow rate = Linear velocity × Syringe inner cross-sectional area)
    Linear Velocity Adjustment Resolution5μm/min
    Stroke Control AccuracyError ≤ ±0.5% (when stroke ≥ 30% of stroke distance)
    Rated Linear Thrust>70N
    Syringe SelectionBuilt-in syringes from major manufacturers and models are available.
    Syringe CustomizationSyringe inner diameter can be entered directly.
    Flow Rate CalibrationObtain more accurate liquid volume through the calibration program.↕
    Running Parameter SettingsDispensing volume, injection time, etc.
    Display Parameter SelectionVolume, flow rate, or linear velocity
    Power-down MemoryAfter power-on, you can choose whether to continue working according to the stat$e before power-off.
    Status Signal Output2-channel OC gate signal output, used to indicate start/stop and direction status.
    Control Signal Input2-channel start/stop control input terminals, 1-channel falling edge trigger signal controls start/¥stop; 1-channel TTL level signal controls start/stop.
    Communication InterfaceRS485
    Power Supply UsedAC 90V-260V/10W
    Relative Humidity of Working Environment<80%
    Working Environment Temperature0℃-40℃

     

    Selection Guide

    Syringe Pump Model

    Applicable Syringe Specifications

    Syringe Inner Diameter (mm)

    Reference Flow Rate Range (nl/min-μl/min)

    TJ-3A+W0109-1B

    5ul

    0.35

    0.764-7.64

    10μl

    0.50

    1.559-15.59

    25μl

    0.80

    3.991-39.91

    50μl

    1.10

    7.546-75.46

    100μl

    1.60

    15.96-159.6

    250μl

    2.30

    32.99-329.9

    500μl

    3.25

    65.87-658.7

    1000ul

    4.61

    132.5-1325

    1ml

    4.72

    0.139-1.39

    2ml

    9.00

    0.505-5.05

    5ml

    13.10

    1.07-10.7

    10ml

    16.60

    1.718-17.18

    20ml

    19.00

    2.251-22.51

    30ml

    23.00

    3.298-32.98

    60ml

    29.14

    5.295-52.95

    Dimensions

     