TJ-3A+W0109-1B split syringe pump
Category:
Tags:
- Product Description
TJ-3A+W0109-1B split syringe pump
-
- Commodity name: TJ-3A+W0109-1B split syringe pump
Flow range: 0.138ul-52.95ml/min, the controller and actuator are separated, suitable for syringes, single-channel perfusion/aspiration type micro-injection pump
Product Introduction
◆ The TJ-3A+W0109 is a single-channel infusion/aspiration microliter syring∏e pump, suitable for high-precision micro-volume liquid' infusion.
◆ Flow Rate Range: 0.138ul-52.95ml/min
◆ Compact size, the controller and actuator are separate.
◆ User-friendly interface: large screen LCD display, digital rotary knob and membrane keypad, easΩy and quick operation.
◆ 5 Working Modes: Infusion mode, Aspiration mode, Aspiration-Infusion mode, Infusion-Aspirati↔on mode, Continuous mode.
◆ Power-down Memory Function: Saves the set parameters, no need to ✘reset after power-on.
◆ Using RS-485 communication bus, it can be connected to a host computer for con←trol through background software.
◆ External Control Interface: With input/output control functions.
◆ Liquid Volume Calibration Function: A more accurate flow rate can be o♦btained through the calibration program.
Typical Applications
◆ Biological Laboratories
◆ Micro-volume liquid infusion.
Technical Parameters
Product Model TJ-3A+W0109-1B Working Mode Infusion, Aspiration, Aspiration then Infusion, Infusion then Aspiration, Cont≈inuous Flow Rate Range 0.138ul-52.95ml/min Number of Syringes that can be Installed 1 Range of Syringes that can be Installed 5uL-60ml Stroke Distance 90mm Stroke Resolution 0.156μm Linear Velocity Range 7.94 um/min-79.4mm/min (Flow rate = Linear velocity × Syringe inner cross-sectional area) Linear Velocity Adjustment Resolution 5μm/min Stroke Control Accuracy Error ≤ ±0.5% (when stroke ≥ 30% of stroke distance) Rated Linear Thrust >70N Syringe Selection Built-in syringes from major manufacturers and models are available. Syringe Customization Syringe inner diameter can be entered directly. Flow Rate Calibration Obtain more accurate liquid volume through the calibration program.↕ Running Parameter Settings Dispensing volume, injection time, etc. Display Parameter Selection Volume, flow rate, or linear velocity Power-down Memory After power-on, you can choose whether to continue working according to the stat$e before power-off. Status Signal Output 2-channel OC gate signal output, used to indicate start/stop and direction status. Control Signal Input 2-channel start/stop control input terminals, 1-channel falling edge trigger signal controls start/¥stop; 1-channel TTL level signal controls start/stop. Communication Interface RS485 Power Supply Used AC 90V-260V/10W Relative Humidity of Working Environment <80% Working Environment Temperature 0℃-40℃ Selection Guide
Syringe Pump Model
Applicable Syringe Specifications
Syringe Inner Diameter (mm)
Reference Flow Rate Range (nl/min-μl/min)
TJ-3A+W0109-1B
5ul
0.35
0.764-7.64
10μl
0.50
1.559-15.59
25μl
0.80
3.991-39.91
50μl
1.10
7.546-75.46
100μl
1.60
15.96-159.6
250μl
2.30
32.99-329.9
500μl
3.25
65.87-658.7
1000ul
4.61
132.5-1325
1ml
4.72
0.139-1.39
2ml
9.00
0.505-5.05
5ml
13.10
1.07-10.7
10ml
16.60
1.718-17.18
20ml
19.00
2.251-22.51
30ml
23.00
3.298-32.98
60ml
29.14
5.295-52.95
Dimensions
Related products
Get a free product quote
Fill in your phone and E-mail information, and we will contact you witεhin one working day to solve your problems as soon as possible.