TS-1B+N*W0109 Multi-channel independent control split syringe pump
Category:
Tags:
- Product Description
TS-1B+N*W0109 Multi-channel independent control split syringe pump
-
- Commodity name: TS-1B+N*W0109 Multi-channel independent control split syringe pump
Multi-channel perfusion/aspiration type, independently controllable, suitable for syring♣es, N is the number of actuators
Product Introduction
◆ The TS-1B+N*W0109-1B is a multi-channel infusion/asp≥iration type independently controlled micro-syringe pump, where N ♥represents the number of actuator units
◆ Four actuator units are independently controlled, sett×ing different volumes and flow rates without interference.
◆ 1-4 actuator units are selectable, and any actuator unit↕ can be turned on or off at any time.
◆ Flow rate range: 0.138ul-52.95ml/min (per actuator unit)
◆ Compact size; the controller and actuator units have≈ a split structure.
◆ Capable of accommodating syringes of different specifications.
◆ User-friendly human-machine interface: large screen LCD dαisplay, digital knob and membrane keypad combination for easy a♠nd quick operation.
◆ Five working modes: infusion mode, aspiration mode, aspiration-infusion m₹ode, infusion-aspiration mode, and continuous mode.
◆ Power-off memory function: automatically saves the set parameters, no need÷ to reset after power-on.
◆ Using a 485 communication bus, it can be connected to a host computer♣ for control via background software.
◆ External control interface: has input/output control functions.
◆ Volume calibration function: a calibration procedure can be used to obtain more accurate flow rates.
Typical Applications
◆ Biological laboratories
◆ Micro-liquid infusion.
Technical Parameters
Product Model TS-1B+N*W0109-1B Working Mode Infusion, Aspiration, Aspiration then Infusion, Infusion then Aspiration, Continuous Flow Rate Range 0.138ul-52.95ml/min Number of Syringes that can be installed 1-4 Range of Syringes that can be installed 1ml-60ml Maximum Stroke 90mm Stroke Resolution 0.156μm Linear Velocity Range 7.94 um/min-79.4mm/min (Flow rate = Linear velocity × Cross-sectional area of syringe) Linear Velocity Adjustment Resolution 5μm/min Stroke Control Accuracy Error ≤ ±0.5% (when stroke ≥ 30% of maximum stroke) Rated Linear Thrust >90N Syringe Selection Built-in selection of major manufacturers and models of syringes Syringe Customization Inner diameter of the syringe can be directly input Flow Rate Calibration Obtain more precise liquid volume through calibratio÷n procedure Operating Parameter Settings Dispensed volume, injection time, etc. Display Parameter Selection Volume, flow rate or linear velocity Power-off Memory After power-on, you can choose whether to continue working according to the status≈ before power-off. Status Signal Output Two-channel OC gate signal output, used to indicate start/stop" and direction status. Control Signal Input Two start/stop control input terminals; one falling edge trigger signal controls start/stop;σ one TTL level signal controls start/stop. Communication Interface RS485 Power Supply Used AC 90V-260V/40W Relative Humidity of Working Environment <80% Working Environment Temperature 0℃-40℃ Selection Guide
Syringe Pump Model
Applicable Syringe (or Injector) Specifications
Applicable Syringe Inner Diameter (mm)
Reference Flow Rate Range (μl/min-ml/min)
TS-1B+W0109-1B
TS-1B+2*W0109-1B
TS-1B+3*W0109-1B
TS-1B+4*W0109-1B
5ul
0.35
0.764-7.64
10μl
0.50
1.559-15.59
25μl
0.80
3.991-39.91
50μl
1.10
7.546-75.46
100μl
1.60
15.96-159.6
250μl
2.30
32.99-329.9
500μl
3.25
65.87-658.7
1000ul
4.61
132.5-1325
1ml
4.72
0.139-1.39
2ml
9.00
0.505-5.05
5ml
13.10
1.07-10.7
10ml
16.60
1.718-17.18
20ml
19.00
2.251-22.51
30ml
23.00
3.298-32.98
60ml
29.14
5.295-52.95